Type-Bp
  1. Wiring diagram:
Wiring diagram are summarized in JGWdoc.

  1. Tower and Payload
A. Cabling check inside the vaccum chamber:
Measurement was performed by checking resistance, inductance, and foreward voltage at feedthrough ports on the vaccum chamber. 
Resistance and forward voltage were measured by digital multimeter “Sanwa CD772”.
Inductance and capacitance were measured by LCR meter “Lutron LCR-9183”.
Inductance was measured at 1kHz.

  • Feedthrough flange position of chamber

  • Port position on the feedthrough flange

  1. Measurement
The cable connections were checked at the feedthroughs (PRM, PR2, PR3)

Pin assign
PR2
PR3
PRM
TMcoil
H1

1-6:
blank
2-7:

3-8:
blank
4-9:
blank
port number: 1-2


16.8 Ω
8.615 mH




port number: 2-8


17.1 Ω
8.586 mH




port number: 1-2


17.3Ω
8.567mH




TMcoil
H2

1-6:
blank
2-7:

3-8:
blank
4-9:
blank
port number: 2-3


16.9 Ω
8.565 mH




port number: 2-5


17.1 Ω
8.582 mH




port number: 1-3


17.5Ω
8.534mH




TMcoil
H3

1-6:
port number: 3-2

port number: 4-7

port number: 4-4